RobDog |
|
|||
|
Any gas gurus out there know if I can do anything to this tank to fit twin lines?
|
|||
Top | |
Nigel |
|
||
|
Multivalve... I dont think you can. However E Series Tanks are a dime a dozen - you should be able to get an APA which you can dual line easy enough. $100 even for inspected ones on ebay
Nigel |
||
Top | |
tickford_6 |
|
||
Posts: 6449 Joined: 11th Nov 2004 |
Why do you need twin lines?
|
||
Top | |
RobDog |
|
|||
|
Goin turbo so probably need more gas than one line can supply
|
|||
Top | |
tickford_6 |
|
||
Posts: 6449 Joined: 11th Nov 2004 |
the shut off valves will be more of a problem.
|
||
Top | |
RobDog |
|
|||
|
tickford_6 wrote: the shut off valves will be more of a problem. Big restriction? Whats the way around that? I think i might be up for a different tank if I wanna go gas |
|||
Top | |
EFFalcon |
|
|||
|
you can get decent lock offs, thats not a problem.
how much power are you looking at going? i've only got a single 3/8 flex line on mine and have 225rwkw.
_________________ FALCN6 - EF GLi Turbo, 20" Rims, Air Bag Suspension, Straight LPG, 225rwkw |
|||
Top | |
RobDog |
|
|||
|
Will be looking at around 250rwkw hopefully if it can be done. Maybe more but much later on.
Got a GRA kit and will get a second converter. Would a single line t-pieced to twin (like yours EFFalcon) do enough for that and leave any room? Or is twin outlets the only way. My bets on the latter |
|||
Top | |
EFFalcon |
|
|||
|
I've never pushed mine past 225, so i don't know how much headroom i've got.
Mines a single flex line, T-Piece in the engine bay, into 2 lockoffs and 2 converters. theres a couple of guys on Xfalcon that are pretty cluey with LPG, so i'd go do some searching there.
_________________ FALCN6 - EF GLi Turbo, 20" Rims, Air Bag Suspension, Straight LPG, 225rwkw |
|||
Top | |
The Panel Van Man |
|
||
|
We just re dyno'd the 383 on show us your injection today 256 rear wheel kw's at 6000rpm on a single 5/16 service line and standard lock offs. Impco vacuum lock offs do flow more than electric ones. But you will still be restricted by the one at the tank. Apa will build dual outlet tanks upon request but do not know how much. Most multi valve conversion [that's what you have] only use 1/4 service line. The multi valve should not restrict it any more than a single valve would [lock off orifice is still the same] The 383 does start to lean out over 6300RPM but that could be the injectors, no need to go there so just rev limited it to 6200. All you may have to have done is a bigger service line. Regards TPVM.
_________________ SALT IS FOR RACING ON. SAUCE IS FOR FISH & CHIPS. |
||
Top | |
The Panel Van Man |
|
||
|
Hi had a another look at your tank yes you do have 1/4 service line. Regards TPVM.
_________________ SALT IS FOR RACING ON. SAUCE IS FOR FISH & CHIPS. |
||
Top | |
RobDog |
|
|||
|
Im guessing ill have to do some upgrades if i want to chase any higher sort of power.
Ill do a bit more research. Thanks guys |
|||
Top | |
RobDog |
|
|||
|
A single outlet might be able to flow enough.. for now anyway
I read on xfalcon and someone reckoned a 3/8 line should be good for 260rwkw. The Panel Van Man wrote: We just re dyno'd the 383 on show us your injection today 256 rear wheel kw's at 6000rpm on a single 5/16 service line and standard lock offs. And if you have done that then might be able to get away with just going good flowing lock-offs and 3/8 line. Ive got two of the same lock-offs at the converters (ones that came with the GRA kit). Would these be good enough? And what about the one at the tank? Better ones? |
|||
Top | |
The Judge |
|
|||
Age: 46 Posts: 141 Joined: 6th Jul 2008 Ride: FORD FE LTD TURBO/ XE TURBO Location: LIVERPOOL |
twin 3/8's at the least. Don't muck about with Gas. Run slightly richer. Gas isn't as forgiving, despite the higher octane which people confuse for meaning it allows more headroom. It's dryer, hotter and the extra octane quickly becomes negligible if you're running a GRA.
_________________ |
|||
Top | |
misk_one |
|
|||
|
as has been said, regardless of how big the gas lines are, the lockoffs are the restriction.
220rwkw is around the safe limit of most single lock off systems. i melted a piston on a single lockoff standard copper line system on 10psi, now have twin lockoffs and twin 8mm lines but im using an APA tank. if you really want it to work just get an APA tank like this... 1.thread in AFL(filler) 2.gauge 3.combined outlet/pressure relief valve(duo valve) 4.standard outlet upside down.
_________________ XG Panelvan |
|||
Top | |